H2S Monitoring
Gas Monitoring
Gas detection is made easier and more affordable, with Acrulog™ gas monitors, designed for harsh environments providing accurate results at the touch of a button with data downloads and graphics available through Custom Acrustat Software.
Acrulog Micro Sampling Technology (MST)
Micro sampling is taking a sample of 30ml or less of gas and being able to accurately generate the same result as that of a larger sample. All Acrulog pumped loggers use MST and the range includes H2S PPM monitor, H2S PPB monitor for low level detection and Dilution monitor for high level H2S environments.
Acrulog™ the Most Advanced Technology in both portable and continuous monitoring of hydrogen sulfide and other VOCs
We offer HIRE options on some H2S monitors.
Waste water treatment plants turn to PCP Group when they want to improve their process
Optimise Treatment
By knowing the concentration of H2S in a specific location with real time monitoring you can optimise treatment by adjusting dosing.
Identify Source of Odour
Odour issues are adressed quickly, reducing public complaints, when the exact source of the problem can be identified.
Precision Provides Advantage
Having a long term overview of H2S Levels allows you to determine the level of corrosion and make informed, intelligent decisions on planned, targeted maintenance.
Range of Monitors
H2S Gas Monitor (PPM)
gas monitor
The Acrulog™ H2S Gas Monitor (PPM) gas monitor is a portable data-logger, designed to survive in the harsh environments typically found within the waste water industry.
Typical Applications
- Odour and corrosion control
- Manhole and wet well monitoring
- Asset management and research studies
- Wastewater treatment plant monitoring
- Ventilation pipes and rising mains
H2S Parts Per Billion Monitor (PPB)
The Acrulog™ H2S Parts Per Billion Monitor (PPB) is a portable gas data-logger designed for indoor and outdoor environmental applications, to record low levels (0-2000PPB) of Hydrogen Sulphide (H2S), at sampling intervals of between 10 minutes and 1 hour
Typical Applications
- Fence line monitoring
- Scrubber outlet monitoring
- Plant perimeter
- Environmental odour control studies
- Corrosion studies
IPX H2S Parts Per Million Monitor (PPM)
The Acrulog™ IPX H2S Parts Per Million Monitor (PPM) for continuous, in-situ, H2S environmental gas monitoring with micro sampling technology (MST). It is designed for indoor and outdoor continual use and will record levels (0-20PPM, 0-50PPM, 0-200PPM, or 0-1000PPM) of H2S with memory backup.
Typical Applications
- Odour and corrosion control
- Manhole and wet well monitoring
- Asset management and research studies
- Wastewater treatment plant monitoring
- Ventilation pipes and rising mains
IPX H2S Dilution Monitor
The Acrulog™ IPX H2S Dilution Monitor is designed for indoor and outdoor continual use and will record levels (0-20ppm, 0-50PPM, 0-200ppm, or 0-1000ppm) of H2S and features remote-draw sampling capability and memory backup
Typical Applications
- Odour and corrosion control
- Manhole and wet well monitoring
- Asset management and research studies
- Wastewater treatment plant monitoring
- Ventilation pipes and rising mains
Differential Pressure Logger
The Acrulog™ Differential Pressure Logger is simple and compact pressure data logger for harsh environmental monitoring.
Typical Applications
- Sewer differential pressure monitoring
- Venting and inducting
- Asset management and research studies
- Scrubber differential pressure monitoring
- Ventilation pipes and rising mains
CONTINUOUS EMISSION MONITOR
The Acrulog CEM is a continuous emissions monitoring modular system. This product can house a variety of loggers from the Acrulog range. The product is available in either one, two or three-point systems and is robust and hard-wearing. Enhanced temperature controlled systems are available with programmable temperature module and insulated chamber.
The Acrulog CEM provides continuous 4-20mA output, and is designed with remote sampling of up to 15 meters. The MST technology reduces issues with high humidity environments, through a combination of its micro sampling technology and inline treatment of humidity.
- 316 stainless steel enclosure
- 4-20mA output per channel
- Quick release to swap monitors in and out
- Simple to callibrate
- Robust and Weatherproof
- 110-240 VAC regulated to 5VDC as standard
- RS485 and 4G LTE – M or NB-IoT (optional)
Custom ACRUSTAT Software
Custom Acrustat software has been designed for easy download and graphing of Acrulog data and configuration of Acrulog loggers. Keep a library of your scientific data for analysis at your fingertips and quickly configure your fleet of loggers for deployment.
- Custom-made package for Acrulog logger data.
- Access to Acrustat server for telemetry logger date (Server access with login requires internet access for Acrulog logger and PC)
- Export data to a variety of formats including .CSV
- Clear log and set time buttons for fast logger reset
- Acrulog logger parameter set-up and configuration
- Automatic connect and pairing (subject to computer system setup and capabilities)
- Instrument and session explorer for data analysis
- Add labels, adjust axis ranges, and print direct
- Join sessions and overlay data on a single graph
Call Now +353 (0)45 863220
Our engineers can assist you in choosing the correct Odour Solution for your specific requirements